Standard Plus

Natural, medical grade, light weight latex examination gloves

Sold as a case of 10 boxes (100 gloves per box)

Code: 105X

Product information

  • MEDICAL GRADE: Unigloves Standard Plus are incredibly comfortable medical-grade, powder-free single-use latex gloves that can be used across a range of industries, including healthcare, cleaning and food processing
  • NATURAL LATEX: High-quality natural latex offers superior levels of elasticity, comfort and tear resistance, with an ambidextrous fit that makes these gloves easy to put on when you’re in a hurry
  • TOUCHSCREEN: Touchscreen-compatible for your convenience, the light-weight construction provides a balance of strength and sensitivity, with a reduced risk of latex allergies (Type I sensitisation)
  • SUPERIOR GRIP: Textured latex provides superior grip, confidence, performance and safety, especially in wet or oily conditions; the beaded cuff offers extra strength during donning and prevents liquid roll back
  • INCLUDES: Medical-grade disposable gloves with a pinhole AQL of 1.5. Tested for compliance to EN374-1 (protection against dangerous chemicals), and EN1186 (food safe)

The Standard Plus glove from Unigloves is the perfect choice for all customers looking for a lightweight, affordable, yet high quality latex glove. In addition, the glove is also ideal for use in the food industry where an affordable latex glove is needed. It provides reliable protection against chemicals and other hazards that may be encountered in various work environments. Whether in the medical, food service or other fields,

The Standard Plus disposable glove from Unigloves offers a cost-effective and reliable solution to the appropriate protective glove needs while providing a high level of comfort.




Colour
Natural
AQL (Freedom from Holes)
1.5
Palm Thickness (mm)
0.08
Finger Thickness (mm)
0.08
External Surface
Fingertip textured
Design
Ambidextrous
Cuff Type
Beaded
Sterile
No
Latex-Free
No
Powder-Free
Yes
Accelerator-Free
No
Silicone-Free
No
Phthalate-Free
Yes
Tested for Use with Chemotherapy Drugs
No
Anti-static
No
Touchscreen compatible
Yes
Gauge
0
Liner Material
Coating Type
Latex (Flat)
Coating Coverage
Fully Dipped
Food Approved
Yes
NitreGrip®
No
NitreGuard®
No
Sanitized® Treated
No
Hydrophobic
No
Reinforced
No
Impact Protection

AQL 1.5

Meets medical standards for pinholes

Free from powder

Reduces risks of latex allergies (Type I sensitisation) and minimises particulate contamination

Free from phthalates

Suitable for contact with food

Tested to EN1186

Suitable for contact with all food types

Tested to EN374 Type B

Resistant to a range of chemicals

Beaded cuff

Beaded cuff provides extra strength during donning and helps prevent liquid roll back

Manufactured with textured fingertips

Textured fingertips provide improved grip, particularly when working in wet or oily conditions

Medium-weight construction

Medium-weight construction provides a balance of strength and sensitivity

Touchscreen compatible

Suitable for use with mobile and tablet displays without removing gloves

Compliant with: Personal Protective Equipment Regulation (EU) 2016/425



EN ISO 374-1:2016+A1:2018 EN ISO 374-4: 2019 (%)
Sodium hydroxide 40% (K) 6 -133.4
Hydrogen peroxide 30% (P) 6 -4.5
Formaldehyde 37% (T) 5 -130.0

EN374-4 Degradation levels indicate the change in puncture resistance of the gloves after exposure to the challenge chemical.

Level 1 2 3 4 5 6
Time >10 >30 >60 >120 >240 >480

This information does not reflect the actual duration of protection in the workplace and the differentiation between mixtures and pure chemicals. The chemical resistance has been assessed under laboratory conditions from samples taken from the palm only and relates only to the chemical tested. It can be different if the chemical is used in a mixture.

It is recommended to check that the gloves are suitable for the intended use because the conditions at the workplace may be different from the type test depending on temperature, abrasion and degradation. When used, protection gloves may provide less resistance to the dangerous chemical due to changes in physical properties. Movement, snagging, rubbing, degradation caused by the chemical contact etc. may reduce the actual use time significantly. For corrosive chemicals, degradation can be the most important factor to consider in selection of chemical resistant gloves.

Before usage, inspect the gloves for any defect or imperfections.

EN ISO 374-5:2016


Bacteria Fungi Virus

The penetration resistance has been assessed under laboratory conditions and relates only to the tested specimen.

PPE certification (2016/425 #B & #C2) provided by: SATRA Technology Europe, Bracetown Business Park, Clonee, D15 YN2P, IRL (2777)

Compliant with: Medical Devices Regulation (EU) 2017/745

Class I Medical Device

Other information
Contains natural rubber latex and accelerators.  THIS PRODUCT MAY CAUSE ALLERGIC REACTIONS, INCLUDING ANAPHYLACTIC RESPONSES.

Food safe
Single use only
Non-sterile
Contains latex
Store between 5 and 40 degrees Celsius
Store in dry conditions
Store away from direct sunlight and heat
Packaging is recyclable
Size (Alpha) Size (Numeric) Code
XS 6 1051
S 7 1052
M 8 1053
L 9 1054
XL 10 1055

For more information please see the Warehouse Data Sheet.